- N.º artículo: 200923
Fanless 4-port Gigabit full managed industrial PoE Layer 2+ Ethernet switch compliant with IEEE802.3at
Highlights:
- 4-Gigabit ports with PoE AF-AT support up to 30Watt per port
- 2x SFP ports for fiber-GBIC e.g. ALL4750/4751-INDU etc.
- PoE Ports 1-4 max. PoE IEEE802.3at 30W
- Layer2+ features like 802.1Q VLAN, Port Isolation IGMP, LLDP, PoE+ Management, IP source Guard, ACLs etc.
- Supports Spanning Tree STP (802.1D) and RSTP (802.1W) and MSTP (802.1s)
- Supports PoE management like PoE scheduling, PoE PD-alive, Port PoE Priority, Soft-Reboot PoE Non-Stop
- Supports G.8032 quick ring protocol. Self-healing <20ms
- Max. PoE budget = 120 watts
- Fanless metal housing with optimized heat dissipation
- Easy to use as a desktop, wall mount or DIN rail device
- Extended temperature range from -40°C ~ +75°C
ALLNET ALL-SGI8104v2PM L2+ managed switch with 4 ports PoE is an industrial switch featuring 4-Port Gigabit 802.3af/at PoE + 2-Port Gigabit SFP optical port. It comes with an IP40 rugged case and redundant power system. The industrial managed switch provides user-friendly but advanced IPv6/IPv4 management interfaces and Soft-reboot PoE Non-stop function.It is the best investment for expanding industrial business or upgrading its network infrastructure.
Intelligent PD–Alive Check for Frozen PDs
The ALL-SGI8104v2PM industrial PoE switch 8 ports can be configured to monitor connected PD’s status in real time. Once the PD stops working and responding, the ALL-SGI8104v2PM will reboot the PoE port power and bring the PD back to work. It also greatly enhances the reliability in that the PoE port will reset the PD power, thus reducing administrator’s management burden.
PoE Schedule Function for Energy Saving
For environmental protection purpose, the ALL-SGI8104v2PM switch Ethernet PoE can effectively control the power supply besides its capability of giving high watts power. The PoE schedule function helps to enable or disable PoE power feeding for each PoE port during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money.
Scheduled PD Re-starting
The ALL-SGI8104v2PM smart switch PoE allows each of the connected PoE IP cameras or PoE wireless access points to reboot at a specific time each week. Therefore, it will reduce the chance of IP camera or AP crash resulting from buffer overflow.
Fast Recovery Redundant Ring for Critical Network Applications
The ALL-SGI8104v2PM supports redundant ring technology and features strong, rapid self-recovery capability to prevent interruptions and external intrusions. It incorporates advanced ITU-T G.8032 ERPS technology, Spanning Tree Protocol (802.1s MSTP), and redundant power input system into customer’s industrial automation network to enhance system reliability and uptime in harsh factory environments. In a certain simple Ring network, the recovery time of data link can be as fast as 20ms.
1588 Time Protocol for Industrial Computing Networks
The ALL-SGI8104v2PM is ideal for telecom and Carrier Ethernet applications, supporting MEF service delivery and timing over packet solutions for IEEE 1588 and synchronous Ethernet.
Strong Layer 2 Features
The ALL-SGI8104v2PM layer 2 Ethernet switch can be programmed for advanced Layer 2 switch management functions such as dynamic port link aggregation, 802.1Q tagged VLAN, Q-in-Q VLAN, private VLAN, Multiple Spanning Tree Protocol (MSTP), QoS, bandwidth control, IGMP snooping and MLD snooping. Via the aggregation of supporting ports, the ALL-SGI8104v2PM allows the operation of a high-speed trunk group that comes with multiple ports and supports fail-over as well.
Efficient and Various Management Methods
For efficient management, the ALL-SGI8104v2PM is equipped with console, Web and SNMP management interfaces.
With the built-in Web-based management interface, it offers an easy-to-use, platform-independent management and configuration facility.
For text-based management, it can be accessed via Telnet and the console port.
For standard-based monitor and management software, it offers SNMPv3 connection which encrypts the packet content at each session for secure remote management.
Intelligent PoE Switch SFP DDM Function
The ALL-SGI8104v2PM supports SFP-DDM (digital diagnostic monitor) function that greatly helps network administrator to easily monitor real-time parameters of the SFP transceivers, such as optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage.
The technical equipment and the stable housing make the switch the ideal solution in the industrial area. Delivery without power supply - please order separately!
Technical Details:
Model | ALL-SGI8104v2PM |
Copper Ports | 4-10/100/1000BASE-T RJ45 auto-sensing ports |
Fiber Ports | 2-100/1000BASE-T SFP interfaces, supports 100/1000Mbps dual mode |
PoE Ports | 4-802.3af/802.3at PoE Injector Ports |
Console Ports | 1 x RS-232-to-RJ45 serial port (115200, 8, N, 1) |
Switch Architecture | Store-and-Forward |
Switch Fabric | 12Gbps/non-blocking |
Throughput | 8.928Mpps @64 bytes |
Address Table | 8K entries |
Share Data Buffer | 4.1 Mb |
Jumbo Frame | 9216 Bytes |
SDRAM | 1Gb |
Flash Memory | 128Mb |
Flow Control | IEEE 802.3x pause frame for full-duplex ; Back pressure for half-duplex |
Reset Button | >2 sec.: Factory default and reset |
Power Supply | 48 ~ 57 VDC, 50/60Hz,Dual DC for PoE support 12VDC ~ 48VDC for non PoE support |
PoE Standards | IEEE 802.3af Power over Ethernet/PSE
IEEE 802.3at Power over Ethernet Plus/PSE |
PoE Power Supply Type | Per Port 52V DC, 300mA. Max. 15.4 watts (IEEE 802.3af)
Per Port 52V DC, 600mA. Max. 30 watts (IEEE 802.3at) |
LED Indicators | Power: Green
Solid on–power work normal,off–power disconnected System:Green Blink–work normally, solid on–soft work abnormal, fast blink–soft upgrade PoE: Yellow Solid on–PoE work normally, Off–PoE doesn’t work, Blink–PoE overload 10/100/1000T RJ45 Interfaces (Port 1 to Port 4): 1000 LNK/ACT (Green), Blink–port connected with data transmission; Solid on–port connected without data transmission 100/1000Mbps SFP Interfaces (Port 5 to Port 6): Green Blink- port connected with data transmission; Solid on- port connected without data transmission |
EMC | Surge Immunity:6KV Per: IEC61000-4-5
ESD Protection: ESD Level 4 Per: IEC61000-4-2;EFT Level 4 Per: IEC61000-4-4 |
Dimension | 145x112x47.2mm |
Weight | 0.6kg |
Working Temperature | -40°C to 75°C |
Storage Temperature | -40°C to 80°C |
Operation Humidity | 5% to 95%, non-condensing |
MTBF | 50,000hrs |
Layer 2 functions
Port configuration | Auto-negotiation
Flow Control Port Mirror: TX/RX/BOTH; Many-to-1 monitor CPU Mirror Traffic statistics |
Link Aggregation | Static link aggregation
LACP(Dynamic Trunk/Static Trunk) Algorithm based on Source/Destination MAC Algorithm based on Source/Destination IP |
MAC Table | Aging Time
Static MAC address Dynamic MAC address management |
VLAN | 4094 Active VLANs
4094 VID 802.1Q Tag VLAN Port VLAN Protocol VLAN MAC VLAN Voice VLAN 802.1ad Q-in-Q tunneling Private VLAN (Protected port) GARP/GVRP |
ACL | 256ACLs
L2, L3 e L4 Time-based ACL IP ACL MAC ACL MAC-IP ACL User-Defined ACL ICMPv6 |
Spanning tree | 802.1D Spanning Tree Protocol (STP)
802.1w Rapid Spanning Tree Protocol (RSTP) 802.1s Multiple Spanning Tree Protocol (MSTP) Loop Guard Root Guard TC-BPDU Guard BPDU Guard BPDU Filter |
Ring Protection | <20ms G.8032 ERPS Ring
Fast Ring ALLNET Ring, < 20ms |
Multicast | 256 groups
IGMP v1/v2/v3 Snooping, Fast Leave MLD Snooping Multicast VLAN IGMP filter MVR Multicast Routing |
QOS | 8 mapping IDs to 8 level priority queues
CoS port-based CoS 802.1p-based CoS DSCP-based Scheduling algorithms SP, WRR, SP+WRR Storm Control (Broadcast, Multicast, Unknown Unicast) Bandwidth control per port SWRR, DWRR for Scheduling Flow Redirect Precedence TOS Rate Limiting(Ingress/Egress) Stri Priority |
Security Features | Port Security
MAC address filter ARP Association (Manual, ARP scanning, DHCP snooping) ARP Protection AAA DAI DoS (Denial of Service) Classification of packages based on: End.MAC, IP End, TCP / UDP Ports, Protocol Type; 802.1x Authentication (port-based e MAC-based) TACACS/TACACS+ Authentication RADIUS Authentication DHCP Filter Guest VLAN SSLv2/SSLv3/TLSv1 SSHv1/SSHv2 Restriction of WEB access based on: IP Address, And. MAC and Port; Port Isolation Loopback detection |
Management | SNMP v1/v2c/v3 with Full Private MIBs
RMON 4 groups WEB (HTTP/HTTPS) CLI (Telnet, Console, SSHv1/v2) Firmware upgrade via console/web/TFTP Configuration Backup/Reload Dual Firmware LLDP Configuration Export/Import CDP Aware OAM (IEEE802.3ah) CFM (IEEE802.1ag) sFlow Telnet Client |
Synchronization,
IEEE1588 |
Support IEEE1588v2 transparent clock |
Other Features | DNS Client
DHCP Relay DHCP Client DHCP Snooping DHCP Option 66 DHCP Option 67 DHCP Option 82 NTP/SNTP Client UPNP UDLD |
PoE management | Total PoE power budget control
Per port PoE function enable/disable PoE admin-mode control PoE port power feeding priority Per PoE port power limitation PD classification detection PD alive check PoE schedule Soft-reboot PoE Non-stop |
Maintenance | Cable Diagnostics
Ping SFP DDM (Digital Diagnostics Monitoring) Thermal protection System log (Local and Remote) Memory and CPU Monitoring Tracert/ Tracert 6 |
Layer 3 functions
Static Routing | IPv4 Unicast: Static Routing (Software Base)
IPv6 Unicast: Static Routing (Software Base) |
IPV6 | IPv6 neighbor discovery (ND)
Path maximum transmission unit (MTU) discovery Internet Control Message Protocol (ICMP) version 6 TCPv6/UDPv6 Ping6 Telnet(v6) Http/Https Interface IPV6 ACL IPV6 |
Anzahl Ports PoE/LAN: | 4/0 |
Belüftung Switch: | Lüfterlos |
Einsatzort Switch: | Industrial DIN |
LAN Geschwindigkeit: | 1Gbit/s |
Management: | full managed |
PoE Budget: | <200 Watt |
PoE Port Leistung: | 30W at |
SFP Geschwindigkeit: | SFP 1GBit |
SFP Port Anzahl: | 2 |